【Scale Inhibitor Flocon285】
Name:Scale Inhibitor Flocon285

Main Applications

Feature of this kind of scale inhibitor:

Flocon 285 is a polycarboxylate aqueous solution, can efficiently control the deposition of

inorganic salt scale at the membrane surface.
1.Can effectively control carbonate scale and magnesium hydroxide scale.
2.Suitable for all major film
3.Recognized by the international drinking water
4.Phosphorus chemicals

Product Nature:
The following is the typical nature of Flocon 285, but should not be thought as supply

indicators. Product Index available on request.

Appearance:  Clear amber liquid
Rate of 20oC: 1.115 to 1.35
pH <2
Range of freezing point: 0 to-3oC

Chemical reaction:

Free from the influence of chlorine or other fungicides of oxidized

Application and dose:

1.Flocon 285 is an aqueous solution of organic acids, and it is corrosive when in condensed state. So you should use anti-corrosion tools to dosing. Such as: 316L stainless steel or plastic, that is, GRP, PVC and PE.

2.The recommended dosing position is the downstream of any filtration equipment or filter

3.Flocon 285 can be miscible with water in any proportion, and it can be used in pure product form or In its aqueous solution form. The recommended minimum dosing concentration is 10% w / w

4.Flocon 285 should be continuously added, and stay proportional with water flow to maintain the recommended dose level

5. Dosing amount is related to water quality and saturation index of the various scaling that existed in concentrated brine. You can use specialized computer software to calculate the scaling index, the best system recovery rate and  dosage forecast.


If you are interested in any brand of scale Inhibitor , please feel free to contact us.